How to maintain the floor?
1. Apply glue. The key purpose of gluing the floor is to better waterproof. And when the installation is glued, the interface can be sealed, which has the effect of prevention and fills a layer of commercial insurance. And the buckle lock design scheme deliberately leaves a glue cavity for glue flow and condensation in the floor, which can accurately lock the floor on the part of the design scheme, reducing the possibility of the Vajra grade edge warping at the joints, and improving the service life of the floor.
2. Common problems in construction process. It was first laid gradually from the foot of the wall. Place the mouth side of the board against the wall, and keep an 11 mm gap between the wall and the long side of the board. Then align the next board with both ends of the long side of the board for a certain angle of view. Press the board hard forward and place it flat on the road. Install in the same way. A floor should be cut to a suitable length, with a gap of 11mm between it and the wall. Use the remaining boards to gradually install in the next row (at least 300 mm). Then point the tongue edge of the new row of boards to the concave groove of the previous row to achieve a certain angle of view. Press the board forward and lay it flat on the road.
3. Laying. Align the long side of the board with the previous board and fold it down. Ensure that the position of this board and the previous board are locked together. Slightly extend the board (together with the previous installed board in the previous row, about 30mm), press it into the front row and issue it. When the three row installation was carried out in the past, the space between the floor and the wall was adjusted to 11mm. Install again in the above way until it is finished.
4. Keep away from dampness and cold. Maintenance floor is sure to use a wet mop or towel to wipe the floor, the surface is no problem, but the interface between the board and the board is very easy to seep, naturally several times there is moisture into it does not matter, but everyone's floor is to use for many years, several times there is moisture into the floor will certainly endanger the service life, to the consumer damage, it seems very inconvenient.
Specification | |
Surface Texture | Wood Texture |
Overall Thickness | 3.7mm |
Underlay(Optional) | EVA/IXPE(1.5mm/2mm) |
Wear Layer | 0.2mm. (8 Mil.) |
Size specification | 935 * 183 * 3.7mm |
Technical data of spc flooring | |
Dimentional stability/ EN ISO 23992 | Passed |
Abrasion resistance/ EN 660-2 | Passed |
Slip resistance/ DIN 51130 | Passed |
Heat resistance/ EN 425 | Passed |
Static load/ EN ISO 24343 | Passed |
Wheel caster resistance/ Pass EN 425 | Passed |
Chemical resistance/ EN ISO 26987 | Passed |
Smoke density/ EN ISO 9293/ EN ISO 11925 | Passed |